Enviro Tech Industrial Products
Enviro Tech Industrial Products
Send Email
0804605761183% Response Rate
Search

Home » Products & Services » Aerosense Carbon Dioxide Transmitter Wholesalers


Aerosense Carbon Dioxide Transmitter Wholesalers

Welcome To Enviro Tech Industrial Products -MOBIL NO - 9871034100

Aerosense Carbon Dioxide Transmitter Wholesalers.

  • Aerosense Series CDT-100-RLY Carbon Dioxide Transmitter.
  • Aerosense Series CDT-300 Carbon Dioxide Transmitter.
  • Aerosense Series CDT-100 Carbon Dioxide Transmitter.

CDT-100 Aerosense Carbon Dioxide Transmitter

REQUEST CALLBACK

CDT-100 Aerosense Carbon Dioxide Transmitter
  • CDT-100 Aerosense Carbon Dioxide Transmitter
  • CDT-100 Aerosense Carbon Dioxide Transmitter
  • CDT-100 Aerosense Carbon Dioxide Transmitter
  • CDT-100 Aerosense Carbon Dioxide Transmitter
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 18,500 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Model NumberCDT-100
Usage/ApplicationDemand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
BrandAerosense
Measurement Range0 to 2000/ 3000/ 5000/ 10000 ppm
Accuracy+-30ppm +-3%
Operating Humidity Range0 to 95% RH
Operating Temperature-10 to 60 deg C
Power24 VDC,AC
Size123x70x43 mm
Storage Temperature-30 to 70 deg C
Storage Temperature for Cold Storage-40 to 70 deg C
Response Time150 seconds
Response Time For Cold Storage70 Seconds
Sampling Interval3 Sec

CDT-100 Aerosense Carbon Dioxide Transmitter Series CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • RS-485 MODBUS output: (4-wired) Modicon MODBUS RTU mode, which follow Modicon Modbus protocol-settable address ID switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch

Model No. CDT-100Carbon Dioxide TransmitterCDT-100-LCDCarbon Dioxide Transmitter with displayCDT-100-CSCarbon Dioxide Transmitter for cold storageCDT-100-CS-LCDCarbon Dioxide Transmitter for cold storage with display CDT-100-M Carbon Dioxide Transmitter with MODBUS Communication CDT-100-M-LCD Carbon Dioxide Transmitter with MODBUS Communication & display
Yes! I am interested

CDT-100-RLY Aerosense Carbon Dioxide Transmitter

REQUEST CALLBACK

CDT-100-RLY Aerosense Carbon Dioxide Transmitter
  • CDT-100-RLY Aerosense Carbon Dioxide Transmitter
  • CDT-100-RLY Aerosense Carbon Dioxide Transmitter
  • CDT-100-RLY Aerosense Carbon Dioxide Transmitter
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 18,500 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
UsageDemand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
ModelSeries CDT-100-RLY
Size123mmx70mmx43mm
Response Time150 seconds
BrandAerosense
Operating Temperature10 to 60 deg C
Storage temperature-30 to 70 deg C

CDT-100-RLY Aerosense Carbon Dioxide Transmitter, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range 2000 ppm (5000/10000 ppm) selectable by jumper. It gives analog and Relay output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (6-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • Models available with SPST (Single Pole, Single Throw, normally open) relay output.
  • Re-Calibration function: 10 minutes’ manual recalibration is executable with TRB-100 tool
Yes! I am interested

CDT-300 Aerosense Carbon Dioxide Transmitter

REQUEST CALLBACK

CDT-300 Aerosense Carbon Dioxide Transmitter
  • CDT-300 Aerosense Carbon Dioxide Transmitter
  • CDT-300 Aerosense Carbon Dioxide Transmitter
  • CDT-300 Aerosense Carbon Dioxide Transmitter
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 18,500 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Model NumberSeries CDT-300
Usage/ApplicationDemand Control Ventilation In Schools,Office Buildings,Hospitals And Other Indoor Environments
BrandAerosense
Size123mmx70mmx43mm
Response Time150 Seconds
Operating Temperature-10 to 60 deg C
Operating Humidity range0 to 95% RH
Storage temperature-30 to 70 deg C
Power24 V Dc

CDT-300 Aerosense Carbon Dioxide Transmitter Series CDT-300, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements. Measurement range upto 70000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:
  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch

Model No.Speci???cations
CDT-300Carbon Dioxide Transmitter
CDT-300-LCDCarbon Dioxide Transmitter with display
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
RP SHARMA (Proprietor)
Enviro Tech Industrial Products
Sales Office, Plot No. X/852, Chand Mohalla, Street No. 11, Gandhi Nagar Industrial Area, Near Ramgareya Gurdwara
Delhi - 110031, India
Call Us: 
Call Response Rate: 83%
Share Us :



Home  |   Profile   |  Products & Services  |  Site Map  |   Contact Us

© Enviro Tech Industrial Products. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Enviro Tech Industrial Products