Aerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter Wholesaler India

Offering you a complete choice of products which include aerosense series dpt-flow differential pressure cum air flow transmitter, aerosense dpt-flow differential pressure transmitter modal dpt-flow-7000-d range 0-7000 pa, dpt-flow aerosense differential pressure transmitter modal dpt-flow-7000-d range 0-7000 pa, aerosense dpt-flow differential pressure transmitter modal dpt-flow-5000-d range 0-5000 pa, dpt-flow aerosense differential pressure transmitter modal dpt-flow-5000-d range 0-5000 pa and aerosense dpt-flow differential pressure transmitter modal dpt-flow-2000-d range 0-2000 pa.

Aerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter

REQUEST CALLBACK

Aerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter
  • Aerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter
  • Aerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter
  • Aerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter
  • +9 Aerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 15,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity12 Piece
Usage/ApplicationAir Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications
Model Name/NumberDPT-FLOW
BrandAerosense Singapore
Voltage24 VAC or VDC. +-10 %
Accuracy+-1 %
Product Weight150 G
Protection TypeAerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter
Part TypeAerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter
Country of OriginMade in India

Aerosense Series DPT-Flow Differential Pressure Cum Air Flow Transmitter

Series DPT-Flow Differential Pressure cum Air Flow Transmitter engineered for building automation in the HVAC/R industry.It measures the volume Flow,Velocity, and static and differential pressure.The DPT-Flow Devices can be connected directly to pressure measurement points in the centrifugal fan.It has an optional Auto-Zero Feature which electronically adjusts the Transmitter Zero at predetermined time intervals Every 10 Minutes. The Auto-Zero adjustment takes 4 seconds.The AZ Calibration eliminates all output signal drift due to thermal,electronic, or mechanical effects.


TECHNICAL SPECIFICATION

  • Service:Dry Air Or Non-Aggressive Gases
  • Measuring Element:Piezo resistive
  • Accuracy:±1 %
  • Thermal Effects:Temperature Compensated Across The Full Spectrum Of Capability
  • Proof Pressure:25 kPa
  • Zero Point Calibration:Automatic Autozero Or Manual Pushbutton
  • Response Time:1.0 to 20 sec selectable via menu
  • Pressure Units Select Via Menu:PA,kPA,mBar,In.WC,MM WC
  • Pressure Output Scale Select Via Menu:100-1000/200-2000/500-5000/700-7000 Depending Upon Models
  • Flow Units Select Via Menu:Volume:m3/s,m3/hr,cfm,l/s
  • Velocity:m/s,ft/min
  • Operating Temperature:-10…50° C With Autozero (-AZ) Calibration-5…50 °C
  • Storage Temperature:-20…70 °C Humidity:0 to 95 % rH,
  • Non Condensing
  • Dimensions:90.0X95.0X36.0 MM
  • Electrical Connections:4-Screw Terminal Block Cable Entry: M16
  • Weight:150 g
  • Mounting:2 each 4.3 MM Screw Holes,One Slotted
  • Materials:ABS
  • Protection standard:IP54
  • Display:2-Line Display 12 Characters/Line
  • Size:46.0X14.5 MM
  • Line 1:Volume or Velocity Measurement
  • Line 2:Pressure Measurement


ELECTRICAL: 
Voltage:

  • Maximum Load:500 Q Power Consumption:<1.0 W Circuit:3-Wire (V Out,24 V, GND)
  • Input:24 VAC or VDC.±10 %
  • Output:0-10 VDC,Selectable Via Jumper
  • Resistance Minimum:1 kQ Current
  • Power Consumption:<1.2 W
  • Circuit:3-wire (mA Out,24 V, GND
  • Input:24 VAC or VDC. ±10 %
  • Output:4-20 mA selectable via jumper

APPLICATION

  • Air Flow Monitoring Across Centrifugal Fans And Blowers
  • In-Duct Air Flow Monitoring
  • VAV Applications

ELECTRICAL CONNECTIONS

AZ-Calibration is a Function in the form of an automatic zeroing circuit built into the PCB.The AZ-Calibration electronically adjusts the transmitter zero at predetermined time intervals Every 10 Minutes.The AZ-calibration eliminates all output signal drift due to thermal,electronic or mechanical effects,as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration The AZ adjustment takes 4 seconds.To avoid conflict with the BAS system,the output and display values will freeze to the latest measured value,after which the device returns to its normal measuring mode.Transmitters equipped with the AZ-calibration are virtually maintenance free


MODEL SELECTION TABLE-
Pressure Range Scalable Via Menu

  • DPT-Flow-1000-D- 0-1000 PA
  • DPT-Flow-2000-D- 0-2000 PA
  • DPT-Flow-5000-D- 0-5000 PA
  • DPT-Flow-7000-D- 0-7000 PA



Additional Information:

  • Item Code: Aerosense-Series-DPT-Flow-Differential-Pressure-Transmitter
  • Production Capacity: www.envirotechdelhi.net
  • Delivery Time: www.envirotechindia.info
  • Packaging Details: www.envirotechdelhi.info
Yes! I am interested

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa

REQUEST CALLBACK

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
  • +9 Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 15,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity12 Piece
Usage/ApplicationAir Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications
Model Name/NumberAerosense DPT-Flow
BrandAerosense
Voltage24 VAC or VDC. +-10 %
Accuracy+-1 %
Product Weight150 g
Country of OriginMade in India

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa


Series DPT-Flow Differential Pressure cum Air Flow Transmitter
engineered for building automation in the HVAC/R industry.It measures the volume Flow,Velocity, and static and differential pressure.The DPT-Flow Devices can be connected directly to pressure measurement points in the centrifugal fan.It has an optional Auto-Zero Feature which electronically adjusts the Transmitter Zero at predetermined time intervals Every 10 Minutes. The Auto-Zero adjustment takes 4 seconds.The AZ Calibration eliminates all output signal drift due to thermal,electronic, or mechanical effects.


TECHNICAL SPECIFICATION

  • Service:Dry Air Or Non-Aggressive Gases
  • Measuring Element:Piezo resistive
  • Accuracy:±1 %
  • Thermal Effects:Temperature Compensated Across The Full Spectrum Of Capability
  • Proof Pressure:25 kPa
  • Zero Point Calibration:Automatic Autozero Or Manual Pushbutton
  • Response Time:1.0 to 20 sec selectable via menu
  • Pressure Units Select Via Menu:PA,kPA,mBar,In.WC,MM WC
  • Pressure Output Scale Select Via Menu:100-1000/200-2000/500-5000/700-7000 Depending Upon Models
  • Flow Units Select Via Menu:Volume:m3/s,m3/hr,cfm,l/s
  • Velocity:m/s,ft/min
  • Operating Temperature:-10…50° C With Autozero (-AZ) Calibration-5…50 °C
  • Storage Temperature:-20…70 °C Humidity:0 to 95 % rH,
  • Non Condensing
  • Dimensions:90.0X95.0X36.0 MM
  • Electrical Connections:4-Screw Terminal Block Cable Entry: M16
  • Weight:150 g
  • Mounting:2 each 4.3 MM Screw Holes,One Slotted
  • Materials:ABS
  • Protection standard:IP54
  • Display:2-Line Display 12 Characters/Line
  • Size:46.0X14.5 MM
  • Line 1:Volume or Velocity Measurement
  • Line 2:Pressure Measurement


ELECTRICAL: 
Voltage:

  • Maximum Load:500 Q Power Consumption:<1.0 W Circuit:3-Wire (V Out,24 V, GND)
  • Input:24 VAC or VDC.±10 %
  • Output:0-10 VDC,Selectable Via Jumper
  • Resistance Minimum:1 kQ Current
  • Power Consumption:<1.2 W
  • Circuit:3-wire (mA Out,24 V, GND
  • Input:24 VAC or VDC. ±10 %
  • Output:4-20 mA selectable via jumper

APPLICATION

  • Air Flow Monitoring Across Centrifugal Fans And Blowers
  • In-Duct Air Flow Monitoring
  • VAV Applications

ELECTRICAL CONNECTIONS

AZ-Calibration is a Function in the form of an automatic zeroing circuit built into the PCB.The AZ-Calibration electronically adjusts the transmitter zero at predetermined time intervals Every 10 Minutes.The AZ-calibration eliminates all output signal drift due to thermal,electronic or mechanical effects,as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration The AZ adjustment takes 4 seconds.To avoid conflict with the BAS system,the output and display values will freeze to the latest measured value,after which the device returns to its normal measuring mode.Transmitters equipped with the AZ-calibration are virtually maintenance free


MODEL SELECTION TABLE-
Pressure Range Scalable Via Menu

  • DPT-Flow-1000-D- 0-1000 PA
  • DPT-Flow-2000-D- 0-2000 PA
  • DPT-Flow-5000-D- 0-5000 PA
  • DPT-Flow-7000-D- 0-7000 PA



Additional Information:

  • Item Code: Aerosense-Modal-DPT-Flow-7000-D-Range-0-7000Pa
  • Production Capacity: www.envirotechindustrialproducts.co.in
  • Delivery Time: www.envirotechindustrialproduct.co.in
  • Packaging Details: www.envirotechindustrialproduct.in
Yes! I am interested

DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa

REQUEST CALLBACK

DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
  • DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
  • DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
  • DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
  • +9 DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 15,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity12 Piece
Usage/ApplicationAir Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications
Model Name/NumberModal DPT-Flow-7000-D Range 0-7000 Pa
BrandAerosense
Voltage24 VAC or VDC. +-10 %
Accuracy+-1 %
Product Weight150 g
Part TypeAerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa
Country of OriginMade in India

DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-7000-D Range 0-7000 Pa

Series DPT-Flow Differential Pressure cum Air Flow Transmitter engineered for building automation in the HVAC/R industry.It measures the volume Flow,Velocity, and static and differential pressure.The DPT-Flow Devices can be connected directly to pressure measurement points in the centrifugal fan.It has an optional Auto-Zero Feature which electronically adjusts the Transmitter Zero at predetermined time intervals Every 10 Minutes. The Auto-Zero adjustment takes 4 seconds.The AZ Calibration eliminates all output signal drift due to thermal,electronic, or mechanical effects.


TECHNICAL SPECIFICATION

  • Service:Dry Air Or Non-Aggressive Gases
  • Measuring Element:Piezo resistive
  • Accuracy:±1 %
  • Thermal Effects:Temperature Compensated Across The Full Spectrum Of Capability
  • Proof Pressure:25 kPa
  • Zero Point Calibration:Automatic Autozero Or Manual Pushbutton
  • Response Time:1.0 to 20 sec selectable via menu
  • Pressure Units Select Via Menu:PA,kPA,mBar,In.WC,MM WC
  • Pressure Output Scale Select Via Menu:100-1000/200-2000/500-5000/700-7000 Depending Upon Models
  • Flow Units Select Via Menu:Volume:m3/s,m3/hr,cfm,l/s
  • Velocity:m/s,ft/min
  • Operating Temperature:-10…50° C With Autozero (-AZ) Calibration-5…50 °C
  • Storage Temperature:-20…70 °C Humidity:0 to 95 % rH,
  • Non Condensing
  • Dimensions:90.0X95.0X36.0 MM
  • Electrical Connections:4-Screw Terminal Block Cable Entry: M16
  • Weight:150 g
  • Mounting:2 each 4.3 MM Screw Holes,One Slotted
  • Materials:ABS
  • Protection standard:IP54
  • Display:2-Line Display 12 Characters/Line
  • Size:46.0X14.5 MM
  • Line 1:Volume or Velocity Measurement
  • Line 2:Pressure Measurement


ELECTRICAL: 
Voltage:

  • Maximum Load:500 Q Power Consumption:<1.0 W Circuit:3-Wire (V Out,24 V, GND)
  • Input:24 VAC or VDC.±10 %
  • Output:0-10 VDC,Selectable Via Jumper
  • Resistance Minimum:1 kQ Current
  • Power Consumption:<1.2 W
  • Circuit:3-wire (mA Out,24 V, GND
  • Input:24 VAC or VDC. ±10 %
  • Output:4-20 mA selectable via jumper

APPLICATION

  • Air Flow Monitoring Across Centrifugal Fans And Blowers
  • In-Duct Air Flow Monitoring
  • VAV Applications

ELECTRICAL CONNECTIONS

AZ-Calibration is a Function in the form of an automatic zeroing circuit built into the PCB.The AZ-Calibration electronically adjusts the transmitter zero at predetermined time intervals Every 10 Minutes.The AZ-calibration eliminates all output signal drift due to thermal,electronic or mechanical effects,as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration The AZ adjustment takes 4 seconds.To avoid conflict with the BAS system,the output and display values will freeze to the latest measured value,after which the device returns to its normal measuring mode.Transmitters equipped with the AZ-calibration are virtually maintenance free


MODEL SELECTION TABLE-
Pressure Range Scalable Via Menu

  • DPT-Flow-1000-D- 0-1000 PA
  • DPT-Flow-2000-D- 0-2000 PA
  • DPT-Flow-5000-D- 0-5000 PA
  • DPT-Flow-7000-D- 0-7000 PA



Additional Information:

  • Item Code: DPT-Flow-7000-D-Range-0-7000-Pa
  • Production Capacity: www.envirotechindustrialproducts.in
  • Delivery Time: www.envirotechindustrialproduct.com
  • Packaging Details: www.envirotechindustrialproducts.com
Yes! I am interested

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa

REQUEST CALLBACK

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
  • +9 Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 15,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity12 Piece
Usage/ApplicationAir Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications
Model Name/NumberDPT-Flow-5000-D Range 0-5000 Pa
BrandAerosense
Voltage24 VAC or VDC. +-10 %
Accuracy+-1 %

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa

Series DPT-Flow Differential Pressure cum Air Flow Transmitter engineered for building automation in the HVAC/R industry.It measures the volume Flow,Velocity, and static and differential pressure.The DPT-Flow Devices can be connected directly to pressure measurement points in the centrifugal fan.It has an optional Auto-Zero Feature which electronically adjusts the Transmitter Zero at predetermined time intervals Every 10 Minutes. The Auto-Zero adjustment takes 4 seconds.The AZ Calibration eliminates all output signal drift due to thermal,electronic, or mechanical effects.


TECHNICAL SPECIFICATION

  • Service:Dry Air Or Non-Aggressive Gases
  • Measuring Element:Piezo resistive
  • Accuracy:±1 %
  • Thermal Effects:Temperature Compensated Across The Full Spectrum Of Capability
  • Proof Pressure:25 kPa
  • Zero Point Calibration:Automatic Autozero Or Manual Pushbutton
  • Response Time:1.0 to 20 sec selectable via menu
  • Pressure Units Select Via Menu:PA,kPA,mBar,In.WC,MM WC
  • Pressure Output Scale Select Via Menu:100-1000/200-2000/500-5000/700-7000 Depending Upon Models
  • Flow Units Select Via Menu:Volume:m3/s,m3/hr,cfm,l/s
  • Velocity:m/s,ft/min
  • Operating Temperature:-10…50° C With Autozero (-AZ) Calibration-5…50 °C
  • Storage Temperature:-20…70 °C Humidity:0 to 95 % rH,
  • Non Condensing
  • Dimensions:90.0X95.0X36.0 MM
  • Electrical Connections:4-Screw Terminal Block Cable Entry: M16
  • Weight:150 g
  • Mounting:2 each 4.3 MM Screw Holes,One Slotted
  • Materials:ABS
  • Protection standard:IP54
  • Display:2-Line Display 12 Characters/Line
  • Size:46.0X14.5 MM
  • Line 1:Volume or Velocity Measurement
  • Line 2:Pressure Measurement


ELECTRICAL: 
Voltage:

  • Maximum Load:500 Q Power Consumption:<1.0 W Circuit:3-Wire (V Out,24 V, GND)
  • Input:24 VAC or VDC.±10 %
  • Output:0-10 VDC,Selectable Via Jumper
  • Resistance Minimum:1 kQ Current
  • Power Consumption:<1.2 W
  • Circuit:3-wire (mA Out,24 V, GND
  • Input:24 VAC or VDC. ±10 %
  • Output:4-20 mA selectable via jumper

APPLICATION

  • Air Flow Monitoring Across Centrifugal Fans And Blowers
  • In-Duct Air Flow Monitoring
  • VAV Applications

ELECTRICAL CONNECTIONS

AZ-Calibration is a Function in the form of an automatic zeroing circuit built into the PCB.The AZ-Calibration electronically adjusts the transmitter zero at predetermined time intervals Every 10 Minutes.The AZ-calibration eliminates all output signal drift due to thermal,electronic or mechanical effects,as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration The AZ adjustment takes 4 seconds.To avoid conflict with the BAS system,the output and display values will freeze to the latest measured value,after which the device returns to its normal measuring mode.Transmitters equipped with the AZ-calibration are virtually maintenance free


MODEL SELECTION TABLE-
Pressure Range Scalable Via Menu

  • DPT-Flow-1000-D- 0-1000 PA
  • DPT-Flow-2000-D- 0-2000 PA
  • DPT-Flow-5000-D- 0-5000 PA
  • DPT-Flow-7000-D- 0-7000 PA



Additional Information:

  • Item Code: Modal-DPT-Flow-5000-D-Range-0-5000-Pa
  • Production Capacity: www.envirotechindustrialproducts.net
  • Delivery Time: www.envirotechindustrialproduct.net
  • Packaging Details: www.envirotechindustrialproductsindia.in
Yes! I am interested

DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa

REQUEST CALLBACK

DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
  • DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
  • DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
  • DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
  • +9 DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 15,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity12 Piece
Usage/ApplicationAir Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications
Model Name/NumberDPT-Flow-5000-D Range 0-5000 Pa
BrandAerosense
Voltage24 VAC or VDC. +-10 %
Accuracy+-1 %
Product Weight150 g
Protection TypeAerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
Part TypeAerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa
Country of OriginMade in India

DPT-Flow Aerosense Differential Pressure Transmitter Modal DPT-Flow-5000-D Range 0-5000 Pa

Series DPT-Flow Differential Pressure cum Air Flow Transmitter engineered for building automation in the HVAC/R industry.It measures the volume Flow,Velocity, and static and differential pressure.The DPT-Flow Devices can be connected directly to pressure measurement points in the centrifugal fan.It has an optional Auto-Zero Feature which electronically adjusts the Transmitter Zero at predetermined time intervals Every 10 Minutes. The Auto-Zero adjustment takes 4 seconds.The AZ Calibration eliminates all output signal drift due to thermal,electronic, or mechanical effects.


TECHNICAL SPECIFICATION

  • Service:Dry Air Or Non-Aggressive Gases
  • Measuring Element:Piezo resistive
  • Accuracy:±1 %
  • Thermal Effects:Temperature Compensated Across The Full Spectrum Of Capability
  • Proof Pressure:25 kPa
  • Zero Point Calibration:Automatic Autozero Or Manual Pushbutton
  • Response Time:1.0 to 20 sec selectable via menu
  • Pressure Units Select Via Menu:PA,kPA,mBar,In.WC,MM WC
  • Pressure Output Scale Select Via Menu:100-1000/200-2000/500-5000/700-7000 Depending Upon Models
  • Flow Units Select Via Menu:Volume:m3/s,m3/hr,cfm,l/s
  • Velocity:m/s,ft/min
  • Operating Temperature:-10…50° C With Autozero (-AZ) Calibration-5…50 °C
  • Storage Temperature:-20…70 °C Humidity:0 to 95 % rH,
  • Non Condensing
  • Dimensions:90.0X95.0X36.0 MM
  • Electrical Connections:4-Screw Terminal Block Cable Entry: M16
  • Weight:150 g
  • Mounting:2 each 4.3 MM Screw Holes,One Slotted
  • Materials:ABS
  • Protection standard:IP54
  • Display:2-Line Display 12 Characters/Line
  • Size:46.0X14.5 MM
  • Line 1:Volume or Velocity Measurement
  • Line 2:Pressure Measurement


ELECTRICAL: 
Voltage:

  • Maximum Load:500 Q Power Consumption:<1.0 W Circuit:3-Wire (V Out,24 V, GND)
  • Input:24 VAC or VDC.±10 %
  • Output:0-10 VDC,Selectable Via Jumper
  • Resistance Minimum:1 kQ Current
  • Power Consumption:<1.2 W
  • Circuit:3-wire (mA Out,24 V, GND
  • Input:24 VAC or VDC. ±10 %
  • Output:4-20 mA selectable via jumper

APPLICATION

  • Air Flow Monitoring Across Centrifugal Fans And Blowers
  • In-Duct Air Flow Monitoring
  • VAV Applications

ELECTRICAL CONNECTIONS

AZ-Calibration is a Function in the form of an automatic zeroing circuit built into the PCB.The AZ-Calibration electronically adjusts the transmitter zero at predetermined time intervals Every 10 Minutes.The AZ-calibration eliminates all output signal drift due to thermal,electronic or mechanical effects,as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration The AZ adjustment takes 4 seconds.To avoid conflict with the BAS system,the output and display values will freeze to the latest measured value,after which the device returns to its normal measuring mode.Transmitters equipped with the AZ-calibration are virtually maintenance free


MODEL SELECTION TABLE-
Pressure Range Scalable Via Menu

  • DPT-Flow-1000-D- 0-1000 PA
  • DPT-Flow-2000-D- 0-2000 PA
  • DPT-Flow-5000-D- 0-5000 PA
  • DPT-Flow-7000-D- 0-7000 PA



Additional Information:

  • Item Code: Modal-DPT-Flow-5000-D-Range-0-5000Pa
  • Production Capacity: www.envirotechindustrialproductsdelhi.com
  • Delivery Time: www.envirotechindustrialproduct.info
  • Packaging Details: www.envirotechindustrialproducts.info
Yes! I am interested

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-2000-D Range 0-2000 Pa

REQUEST CALLBACK

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-2000-D Range 0-2000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-2000-D Range 0-2000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-2000-D Range 0-2000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-2000-D Range 0-2000 Pa
  • +9 Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-2000-D Range 0-2000 Pa
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 15,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity12 Piece
Usage/ApplicationAir Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications
Model Name/NumberDPT-Flow-2000-D Range 0-2000 Pa
BrandAerosense
Voltage24 VAC or VDC. +-10 %
Accuracy+-1 %
Product Weight150 g
Part TypeAerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-2000-D Range 0-2000 Pa
Country of OriginMade in India

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-2000-D Range 0-2000 Pa

Series DPT-Flow Differential Pressure cum Air Flow Transmitter engineered for building automation in the HVAC/R industry.It measures the volume Flow,Velocity, and static and differential pressure.The DPT-Flow Devices can be connected directly to pressure measurement points in the centrifugal fan.It has an optional Auto-Zero Feature which electronically adjusts the Transmitter Zero at predetermined time intervals Every 10 Minutes. The Auto-Zero adjustment takes 4 seconds.The AZ Calibration eliminates all output signal drift due to thermal,electronic, or mechanical effects.


TECHNICAL SPECIFICATION

  • Service:Dry Air Or Non-Aggressive Gases
  • Measuring Element:Piezo resistive
  • Accuracy:±1 %
  • Thermal Effects:Temperature Compensated Across The Full Spectrum Of Capability
  • Proof Pressure:25 kPa
  • Zero Point Calibration:Automatic Autozero Or Manual Pushbutton
  • Response Time:1.0 to 20 sec selectable via menu
  • Pressure Units Select Via Menu:PA,kPA,mBar,In.WC,MM WC
  • Pressure Output Scale Select Via Menu:100-1000/200-2000/500-5000/700-7000 Depending Upon Models
  • Flow Units Select Via Menu:Volume:m3/s,m3/hr,cfm,l/s
  • Velocity:m/s,ft/min
  • Operating Temperature:-10…50° C With Autozero (-AZ) Calibration-5…50 °C
  • Storage Temperature:-20…70 °C Humidity:0 to 95 % rH,
  • Non Condensing
  • Dimensions:90.0X95.0X36.0 MM
  • Electrical Connections:4-Screw Terminal Block Cable Entry: M16
  • Weight:150 g
  • Mounting:2 each 4.3 MM Screw Holes,One Slotted
  • Materials:ABS
  • Protection standard:IP54
  • Display:2-Line Display 12 Characters/Line
  • Size:46.0X14.5 MM
  • Line 1:Volume or Velocity Measurement
  • Line 2:Pressure Measurement


ELECTRICAL: 
Voltage:

  • Maximum Load:500 Q Power Consumption:<1.0 W Circuit:3-Wire (V Out,24 V, GND)
  • Input:24 VAC or VDC.±10 %
  • Output:0-10 VDC,Selectable Via Jumper
  • Resistance Minimum:1 kQ Current
  • Power Consumption:<1.2 W
  • Circuit:3-wire (mA Out,24 V, GND
  • Input:24 VAC or VDC. ±10 %
  • Output:4-20 mA selectable via jumper

APPLICATION

  • Air Flow Monitoring Across Centrifugal Fans And Blowers
  • In-Duct Air Flow Monitoring
  • VAV Applications

ELECTRICAL CONNECTIONS

AZ-Calibration is a Function in the form of an automatic zeroing circuit built into the PCB.The AZ-Calibration electronically adjusts the transmitter zero at predetermined time intervals Every 10 Minutes.The AZ-calibration eliminates all output signal drift due to thermal,electronic or mechanical effects,as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration The AZ adjustment takes 4 seconds.To avoid conflict with the BAS system,the output and display values will freeze to the latest measured value,after which the device returns to its normal measuring mode.Transmitters equipped with the AZ-calibration are virtually maintenance free


MODEL SELECTION TABLE-
Pressure Range Scalable Via Menu

  • DPT-Flow-1000-D- 0-1000 PA
  • DPT-Flow-2000-D- 0-2000 PA
  • DPT-Flow-5000-D- 0-5000 PA
  • DPT-Flow-7000-D- 0-7000 PA




Additional Information:

  • Item Code: Modal-DPT-Flow-2000-D-Range-0-2000-Pa
  • Production Capacity: www.envirotechdelhi.co.in
  • Delivery Time: www.envirotechindia.net
  • Packaging Details: www.envirotechdelhi.info
Yes! I am interested

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa

REQUEST CALLBACK

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa
  • Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa
  • +9 Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 15,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity24 Piece
Usage/ApplicationAir Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications
Model Name/NumberDPT-Flow-1000-D Range 0-1000 Pa
BrandAerosense
Voltage24 VAC or VDC. +-10 %
Accuracy+-1 %
Product Weight150 g
Protection TypeAerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa
Part TypeAerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa

Aerosense DPT-Flow Differential Pressure Transmitter Modal DPT-Flow-1000-D Range 0-1000 Pa

Series DPT-Flow Differential Pressure cum Air Flow Transmitter engineered for building automation in the HVAC/R industry.It measures the volume Flow,Velocity, and static and differential pressure.The DPT-Flow Devices can be connected directly to pressure measurement points in the centrifugal fan.It has an optional Auto-Zero Feature which electronically adjusts the Transmitter Zero at predetermined time intervals Every 10 Minutes. The Auto-Zero adjustment takes 4 seconds.The AZ Calibration eliminates all output signal drift due to thermal,electronic, or mechanical effects.


TECHNICAL SPECIFICATION

  • Service:Dry Air Or Non-Aggressive Gases
  • Measuring Element:Piezo resistive
  • Accuracy:±1 %
  • Thermal Effects:Temperature Compensated Across The Full Spectrum Of Capability
  • Proof Pressure:25 kPa
  • Zero Point Calibration:Automatic Autozero Or Manual Pushbutton
  • Response Time:1.0 to 20 sec selectable via menu
  • Pressure Units Select Via Menu:PA,kPA,mBar,In.WC,MM WC
  • Pressure Output Scale Select Via Menu:100-1000/200-2000/500-5000/700-7000 Depending Upon Models
  • Flow Units Select Via Menu:Volume:m3/s,m3/hr,cfm,l/s
  • Velocity:m/s,ft/min
  • Operating Temperature:-10…50° C With Autozero (-AZ) Calibration-5…50 °C
  • Storage Temperature:-20…70 °C Humidity:0 to 95 % rH,
  • Non Condensing
  • Dimensions:90.0X95.0X36.0 MM
  • Electrical Connections:4-Screw Terminal Block Cable Entry: M16
  • Weight:150 g
  • Mounting:2 each 4.3 MM Screw Holes,One Slotted
  • Materials:ABS
  • Protection standard:IP54
  • Display:2-Line Display 12 Characters/Line
  • Size:46.0X14.5 MM
  • Line 1:Volume or Velocity Measurement
  • Line 2:Pressure Measurement


ELECTRICAL: 
Voltage:

  • Maximum Load:500 Q Power Consumption:<1.0 W Circuit:3-Wire (V Out,24 V, GND)
  • Input:24 VAC or VDC.±10 %
  • Output:0-10 VDC,Selectable Via Jumper
  • Resistance Minimum:1 kQ Current
  • Power Consumption:<1.2 W
  • Circuit:3-wire (mA Out,24 V, GND
  • Input:24 VAC or VDC. ±10 %
  • Output:4-20 mA selectable via jumper

APPLICATION

  • Air Flow Monitoring Across Centrifugal Fans And Blowers
  • In-Duct Air Flow Monitoring
  • VAV Applications

ELECTRICAL CONNECTIONS

AZ-Calibration is a Function in the form of an automatic zeroing circuit built into the PCB.The AZ-Calibration electronically adjusts the transmitter zero at predetermined time intervals Every 10 Minutes.The AZ-calibration eliminates all output signal drift due to thermal,electronic or mechanical effects,as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration The AZ adjustment takes 4 seconds.To avoid conflict with the BAS system,the output and display values will freeze to the latest measured value,after which the device returns to its normal measuring mode.Transmitters equipped with the AZ-calibration are virtually maintenance free


MODEL SELECTION TABLE-
Pressure Range Scalable Via Menu

  • DPT-Flow-1000-D- 0-1000 PA
  • DPT-Flow-2000-D- 0-2000 PA
  • DPT-Flow-5000-D- 0-5000 PA
  • DPT-Flow-7000-D- 0-7000 PA




Additional Information:

  • Item Code: Modal-DPT-Flow-1000-D-Range-0-1000-Pa
  • Production Capacity: www.envirotechindia.info
  • Delivery Time: www.envirotechdelhi.net
  • Packaging Details: www.envirotechdelhi.in
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
RP SHARMA (Proprietor)
Enviro Tech Industrial Products
Sales Office, Plot No. X/852, Chand Mohalla, Street No. 11, Gandhi Nagar Industrial Area, Near Ramgareya Gurdwara
Delhi - 110031, India
Call Us: 
Call Response Rate: 83%
Share Us :



Home  |   Profile   |  Products & Services  |  Site Map  |   Contact Us

© Enviro Tech Industrial Products. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Enviro Tech Industrial Products